Lucene search

K
SiemensSimatic S7-1500 Cpu Firmware*

13 matches found

CVE
CVE
added 2022/04/12 9:15 a.m.141 views

CVE-2022-25622

The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by send...

7.5CVSS6.2AI score0.00117EPSS
CVE
CVE
added 2019/10/10 2:15 p.m.110 views

CVE-2019-10936

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.

7.5CVSS7.5AI score0.01992EPSS
CVE
CVE
added 2014/08/17 11:55 p.m.58 views

CVE-2014-5074

Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets.

7.1CVSS6.8AI score0.13713EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.44 views

CVE-2014-2253

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets.

6.1CVSS6.7AI score0.0016EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.43 views

CVE-2014-2251

The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors.

8.3CVSS6.7AI score0.00902EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.43 views

CVE-2014-2257

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets.

7.8CVSS6.7AI score0.00902EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.41 views

CVE-2014-2246

Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

4.3CVSS5.8AI score0.00508EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.41 views

CVE-2014-2259

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets.

7.8CVSS6.7AI score0.01597EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.40 views

CVE-2014-2255

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets.

7.8CVSS6.7AI score0.01597EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.39 views

CVE-2014-2248

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.

4.3CVSS6.9AI score0.0069EPSS
CVE
CVE
added 2016/02/08 4:59 p.m.38 views

CVE-2016-2200

Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102.

7.8CVSS7.4AI score0.09239EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.37 views

CVE-2014-2247

The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors.

5.8CVSS6.9AI score0.00676EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.35 views

CVE-2014-2249

Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.

5.8CVSS7.2AI score0.00181EPSS